Details
FD12-30kw electric yaw wind turbine on grid system:
30kw electric yaw wind turbine + 30kw PWM PLC intelligent on grid controller with dump load + 30kw 380vac 50hz wind power grid tie inverter:
1.) 30kw electric ya wind turbine normal spec
Blades rotor Diameter (m) |
12 |
Working Voltage |
380VAC 3 PHASE |
Blade Material/Quantity |
Reinforced FRP X 3pcs |
Charge Method |
Constant Voltage |
Rated Power/ Maximum Power (W) |
30000/35000 |
Speed Governing Method |
Yawing + Manual Yaw Shutdown |
Rated Wind Speed (m/s) |
12 |
Parking Method |
Electromagnetic Brake + Manual Brake |
Start-up Wind Speed (m/s) |
3 |
Generator Type |
Three-phase AC Permanent Magnet |
Working Wind Speed (m/s) |
3-20 |
Tower weight (KG) |
2840 |
Safe Wind Speed (m/s) |
35 |
Generator(KG) |
1500 |
2.) 30kw PWM PLC intelligent on grid controller with dump load normal spec:
Type |
FT-GT-Y-30KW |
Wind turbine rated power |
30KW |
Wind turbine rated voltage |
AC380V |
Grid voltage |
AC230V |
Function |
Rectifier,control,DC output, Yaw Control |
Automatic protection function |
Over voltage protection, network electric cut off protection, regulated supply output, arrester, Yaw control |
Manual function |
Manual brake, reset, emergency switch |
Display mode |
Touch Screen User Name/Passwords: JNDM |
Display content |
Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. Yaw data Settings |
PWM constant voltage |
550Vdc±1% |
Wind turbine deflection 45°(adjustable) |
550Vdc±1% |
wind turbine 3-phase dump load voltage |
580Vdc±1% |
Wind turbine deflection 90°(adjustable) |
580Vdc±1% |
Time-lapse of the wind turbine 3-phase dump load2 |
12-20 min |
Wind speed(adjustable) |
≥2m/s |
Wind direction(adjustable) |
0-360° |
PWM dump load breaker |
80A |
DC output breaker |
100A |
Self-provided connecting wire of the DC output (mm²) |
>12mm²BVR cable(≤10m Do not use jacketed wire, increase the wire diameter if necessary) |
Self-provided connecting wire of the PWM dump load (mm²) |
>12mm²BVR cable(≤10m Do not use jacketed wire, increase the wire diameter if necessary) |
Self-provided connecting wire of the Three phase dump load (mm²) |
>12mm²BVR cable(≤10m Do not use jacketed wire, increase the wire diameter if necessary) |
Three - phase wind turbine line is connected according to standard distribution line |
|
Work environment temperature |
-30-60°C |
Relative humidity |
<90% No condensation |
Noise (1m) |
<40dB |
Degree of protection |
IP20(Indoor) |
Cooling method |
Forced air cooling |
Communication interface |
RS485/WIFI |
3.) 30kw 380vac 50hz LLLN 3 phase wind power grid tie inverter
Type |
FT-GT-Y-30KW |
Wind turbine rated power |
30KW |
Wind turbine rated voltage |
AC380V |
Grid voltage |
AC230V |
Function |
Rectifier,control,DC output, Yaw Control |
Automatic protection function |
Over voltage protection, network electric cut off protection, regulated supply output, arrester, Yaw control |
Manual function |
Manual brake, reset, emergency switch |
Display mode |
Touch Screen User Name/Passwords: JNDM |
Display content |
Wind turbine voltage, current, power; Solar voltage, current, power; DC output voltage, DC output current, DC output power, total power. Yaw data Settings |
PWM constant voltage |
550Vdc±1% |
Wind turbine deflection 45°(adjustable) |
550Vdc±1% |
wind turbine 3-phase dump load voltage |
580Vdc±1% |
Wind turbine deflection 90°(adjustable) |
580Vdc±1% |
Time-lapse of the wind turbine 3-phase dump load2 |
12-20 min |
Wind speed(adjustable) |
≥2m/s |
Wind direction(adjustable) |
0-360° |
PWM dump load breaker |
80A |
DC output breaker |
100A |
Self-provided connecting wire of the DC output (mm²) |
>12mm²BVR cable(≤10m Do not use jacketed wire, increase the wire diameter if necessary) |
Self-provided connecting wire of the PWM dump load (mm²) |
>12mm²BVR cable(≤10m Do not use jacketed wire, increase the wire diameter if necessary) |
Self-provided connecting wire of the Three phase dump load (mm²) |
>12mm²BVR cable(≤10m Do not use jacketed wire, increase the wire diameter if necessary) |
Three - phase wind turbine line is connected according to standard distribution line |
|
Work environment temperature |
-30-60°C |
Relative humidity |
<90% No condensation |
Noise (1m) |
<40dB |
Degree of protection |
IP20(Indoor) |
Cooling method |
Forced air cooling |
Communication interface |
RS485/WIFI |